• Siemens Approved Partner
  • Customer Credit Accounts
Photoelectric sensor, polarized retro.reflective, 4m, AC/DC, transistor output PNP

Photoelectric sensor, polarized retro.reflective, 4m, AC/DC, transistor output PNP

Omron

Part No: E3JM-R4R4-G

Back Order Item

Out of Stock

Price: £179.70

-
+

Product Specifications

  • Ambient temperature (°C)
    -25 - 55
  • Analogue output 0 mA ... 20 mA
    false
  • Analogue output 0 V ... 10 V
    false
  • Analogue output -10 V ... +10 V
    false
  • Analogue output 4 mA ... 20 mA
    false
  • Construction type housing
    Cuboid
  • Degree of protection (IP)
    IP66
  • Diameter sensor (mm)
  • Explosion safety category for dust
    None
  • Explosion safety category for gas
    None
  • Laser protection class
    None
  • Length of sensor (mm)
    75
  • Light dot (mm²)
    32000
  • Material housing
    Plastic
  • Material of optical surface
    Plastic
  • Max. output current at protected output (mA)
  • Min. reflector distance (mm)
    1000
  • Number of contact energized outputs with signalling function
    0
  • Number of protected contact energized outputs
    0
  • Number of protected semiconductor outputs
    0
  • Operation agent-safety class
    Safety class 0
  • Pre failure notice
    false
  • Rated control supply voltage Us at AC 50HZ (V)
    24 - 240
  • Rated control supply voltage Us at AC 60HZ (V)
    24 - 240
  • Rated control supply voltage Us at DC (V)
    12 - 240
  • Reflector included
    true
  • Setting procedure
    Manual adjustment
  • Suitable for safety functions
    false
  • Switch function
    Light-/dark switching
  • Switching voltage of OSSD at state "high" (V)
  • Transmission range of the safety field (m)
  • Type of electric connection
    Screw connection
  • Type of interface for safety communication
    Other
  • Type of light
    Polarized red light
  • Type of safety acc. IEC 61496-1
    1
  • Type of switch function
    Programmable/configurable
  • Type of switching output
    PNP
  • Voltage type
    AC/DC
  • With communication interface analog
    false
  • With communication interface AS-Interface
    false
  • With communication interface CANOpen
    false
  • With communication interface DeviceNet
    false
  • With communication interface Ethernet
    false
  • With communication interface INTERBUS
    false
  • With communication interface PROFIBUS
    false
  • With communication interface RS-232
    false
  • With communication interface RS-422
    false
  • With communication interface RS-485
    false
  • With communication interface SSD
    false
  • With communication interface SSI
    false
  • With monitoring function downstream switching devices
    false
  • With other analog output
    false
  • With restart blockage
    false
  • With time function
    false